USAfixTM - Repair Guide (RG) - Master Email RG
- Replace the manual valve linkage
 Level of Difficulty - LOW  Estimated Completion Time - 15 minutes
TASKI - SWINGO 750B

Tools Required

Parts Required
PartDescriptionPriceAvailablePurchase
192-8756 Rod (OBSOLETE) $14.97 Back Order Qty:


Step Procedure & Parts & Tools
1 LOCATE THE DRAIN HOSES ON THE BACK OF THE MACHINE

2 PULL TO REMOVE THE RED CAPPED HOSE FROM MACHINE. PLACE HOSE NEAR DRAIN AND REMOVE CAP

3 PULL TO REMOVE THE BLUE CAPPED HOSE FROM MACHINE. PLACE HOSE NEAR DRAIN AND REMOVE CAP

4 LOCATE THE MANUAL VALVE LINKAGE

5 PULL TO REMOVE THE BLUE CAPPED HOSE FROM THE MANUAL SOLUTION VALVE ASSEMBLY

6 TURN THE MANUAL SOLUTION VALVE A 1/4 OF A TURN TO THE LEFT

7 UNHOOK THE LINKAGE FROM THE MANUAL SOLUTION VALVE TO DISCONNECT IT FROM THE MACHINE

8 UNHOOK THE LINKAGE FROM THE MANUAL VALVE LEVER TO DISCONNECT IT FROM THE MACHINE

9 REVERSE STEPS 5 THRU 8 TO INSTALL THE NEW MANUAL VALVE LINKAGE. FILL THE SOLUTION TANK IF NEEDED.

PartDescriptionPriceQty
192-8756 Rod (OBSOLETE) $14.97 Qty: